Как установить вентиляционный канал

Установить вентиляционный канал
Install Ventilation Duct Ventilation duct mainly refers to the ventilation duct of central air conditioning system, which we often ignore it, but it is an important part of air conditioning system. It is a kind of metal or composite pipe for ventilation and air conditioning engineering of industrial and civil buildings. It is a municipal infrastructure to make the air circulate and reduce the concentration of harmful gases.
Classification of Usage
Divided into: supply and return air pipe of the purification system, ventilation pipe of central air conditioning, industrial supply, and exhaust air pipe, suction and exhaust air pipe of the environmental protection system, mine gas drainage pipe, mine rubber-coated cloth air duct, etc. Install Ventilation Duct
Classification of Shape
Делится на: воздуховод круглый, прямоугольный, спиральный воздуховод. Install Ventilation Duct
Классификация технологий обработки
Divided into: angle iron flange duct, TDF flange duct. Install Ventilation Duct

заявка
The air duct is mainly used in industrial and construction engineering, and its application fields mainly involve: purification system of the dust-free workshop in electronic industry, purification system of the aseptic workshop for medicine and food, central air conditioning system of hotels, shopping malls, hospitals, factories and office buildings, exhaust duct for dust removal, smoke extraction and oil absorption in industrial pollution control, supply duct for the industrial environment or post comfort, air duct for air-conditioning, air-conditioning system for air-conditioning and air-conditioning Gas drainage system for coal mine gas drainage, air supply and return system for coal mine environment control, etc. Install Ventilation Duct
Конструкция воздуховода
- For more complex civil buildings, in the design stage, each type of work (HVAC, water supply and drainage, power supply and lighting, and Architecture) should first negotiate the space separation, and determine the elevation range of each kind of pipe. In general, they should not go beyond the limits set for themselves. In case of the crossing of individual pipe sections, it is necessary to negotiate with other projects. Install Ventilation Duct
- The principle to solve the collision and coordination of various ventilation pipes is generally: “small pipes give way to large pipes, and pressure gives way to no pressure”. For example, if the water pipe collides with the air pipe, the water pipe should be turned. If the cold and hot water pipes collide with the downpipe, the cold and hot water pipes should be changed. Install Ventilation Duct
- Before construction, the Engineer in charge of the main equipment shall draw the pipelines and single lines of each type of work on a plan. One-color pen for each type of pipe. Integrate the elevation of each intersection to see if there is any contradiction, find it in time, and solve the problem before installation. Install Ventilation Duct
- In order to reduce investment, save space and reduce floor height, some pipes without slope requirements can be laid through beams (such as water pipes, fire spray pipes, etc.). Install Ventilation Duct

Распространенные проблемы при установке воздуховодов
- Материал не соответствует требованиям качества
This kind of problem is a headache. If the material does not meet the requirements, the air duct will leak when the system is running, which will cause the loss of air conditioning load and affect the service life of the air duct. Install Ventilation Duct

- Шум в воздуховоде
Это явление может быть вызвано неровной поверхностью, неравномерной толщиной, явными вмятинами, трещинами, песчаными отверстиями, рубцами и коррозией пластины или плоским опусканием вентиляционного канала, выступающей наружу стороной и явной деформацией.
- The warping angle, twist and elbow angle of ventilation duct are not accurate Install Ventilation Duct
This is due to the inaccurate setting out of plate cutting; The length and width of the sheet metal on the opposite side are not equal; The width of the undercut at the four corners of the ventilation duct is not equal; The setting position of bite seam is wrong, and the force of manual bite seam is different; Taking no corresponding reinforcement measures. In this case, the relative plane of the rectangular duct is not parallel, and the two ends are not parallel; The angle is not straight; The diagonals are not equal; Install Ventilation Duct
The bite is not tight. The final direct result is that the air duct connection is uneven, the installed air duct is not straight, the flange gasket is not tight, the system air leakage, resulting in air conditioning load loss, and shortens the service life. Install Ventilation Duct
Меры предосторожности при установке воздуховода

1. Перед установкой проверьте качество материалов.
Carefully measure the thickness of the steel plate. Before the installation of the air duct, the factory certificate and material quality certificate of the material must be checked first, and then the appearance of the material must be checked; Then measure the thickness of the steel plate. Prevent rework due to non-conforming materials. Install Ventilation Duct
2. Безопасность подъема должна быть гарантирована.
The hoisting of the clean air duct is the same as that of the ordinary ventilation duct, and the suspender, cross arm, expansion bolt, and lower skid of the insulation air duct are required to meet the relevant specifications and quality acceptance standards. Install Ventilation Duct

3. Обратите внимание на то, чтобы развернуть ступеньки заглушки.
The construction personnel should strictly check the sheet metal, and control the length, width, and diagonal of each sheet metal within the allowable range; After blanking, the two sheets on the opposite side of the air duct should overlap to check the accuracy of the size; The reserved size of sheet bite must be correct to ensure the same width of bite; The biting seam sets at the four corners. When the biting seam is closed by hand, the center of both ends of the biting seam shall be tightened with a wooden hammer, and then the biting seam shall be uniformly compacted along the whole length. Install Ventilation Duct
4. Проведите хорошую проверку на утечку света.
After the ventilation duct assembles on the ground, the light leakage inspection should carry out before the heat preservation. According to the site conditions, the light leakage inspection can be carried out according to the internal or external light leakage, and the sealant shall be added at the light leakage, and the heat preservation can be carried out only when there is no light leakage. Install Ventilation Duct

5. Испытание на утечку воздуха.
For the supply and return air main pipe and branch pipe of purification system with higher grade, besides light leakage inspection, air leakage test shall be conducted after ground assembly. For the smaller system, it can be tested after the installation of the air duct, and for the larger system, it can be carried out after the segmented assembly on the ground as far as possible, so as to find problems and deal with them in time. Install Ventilation Duct
6. Материал подушки должен быть правильно выбран.
The gasket at the flange connection of the ventilation duct shall be made of airtight, dust-free, elastic, and non-aging materials, such as closed cell sponge rubber plate, soft rubber plate, etc. the thickness of the gasket shall be 5-8mm. The joint shall be processed into ladder shape, and direct butt joint is strictly prohibited. Install Ventilation Duct
Это можно резюмировать одним предложением, как правильно установить воздуховод чрезвычайно важен, ниже описаны некоторые установки воздуховодов с более подробными подробными шагами, чтобы уменьшить потери, вызванные проблемами установки.
- Перед установкой убедитесь, что фундаментные работы завершены
The installation of the ventilation duct must be carried out after the completion of these foundation works; Before installation, the appearance quality shall be inspected, and the dust on the inner and outer surface and the debris in the pipe shall be removed. Install Ventilation Duct

● Сборный вентиляционный канал.
Если он не будет устанавливаться временно, его не следует размещать по собственному желанию. Все отверстия в трубах следует обернуть пластиковой тканью и сложить в помещении в соответствии с номером системы, насколько это возможно. Если условия не позволяют это сделать, его необходимо штабелировать на открытом воздухе и обратить внимание на то, чтобы поместить древесину подушки под воздуховод, а выше должны быть надежные водонепроницаемые, ветрозащитные песчаные и солнцезащитные меры.
● Очистите вентиляционный канал.
Воздуховод следует очищать нейтральным моющим средством, которое не вызывает коррозии поверхности плиты, не оставляет пыли после высыхания и не причиняет вреда человеческому телу. Сначала очистите с помощью чистящего раствора, затем протрите чистой водой и, наконец, вытрите водяной знак чистой белой тканью. Если он не установлен, пока его можно сушить естественным путем, но после высыхания воздуховыпускное отверстие следует закрыть.
● Содержите вентиляционный канал в чистоте и порядке.
Персонал, выполняющий монтаж, должен носить чистую рабочую одежду, перчатки и рабочую обувь. Воздуховод и его компоненты, которые были очищены и запломбированы, не подлежат разборке перед установкой. При установке снимите концевую герметизирующую пленку, а затем подсоедините разъем; Если в середине установки возникла пауза, необходимо снова закрыть порт, чтобы обеспечить очистку системы кондиционирования воздуха.
● Прокладка других трубопроводов в вентиляционном канале запрещена.
Линия электропередачи осевой вентилятор, electric heater, and other equipment installed in the ventilation duct system shall be protected and insulated. The fixed cable of the outdoor riser is strictly prohibited to be pulled on the lightning rod or lightning protection network. When the air duct passes through the wall or floor, it shall not be installed in the wall or floor.
The distance between the air duct and the wall should not be less than 200 mm, and the distance between the air duct and the floor should not be less than 150 mm. When the air duct passes through the fireproof and explosion-proof floor or wall that needs to be closed, the embedded pipe or protective sleeve with the wall thickness of not less than 1.6 mm shall be set, and the flexible material that is non-combustible and harmless to the human body shall be used between the air duct and the protective sleeve.

- Монтаж вентиляционного канала должен соответствовать проектным требованиям.
The location of the reserved holes in the building structure should be correct, and the holes should be more than 100 mm larger than the outside size of the air duct. The connection interface between the air duct and the air duct of the building structure should be inserted along the airflow direction, and sealing measures should be taken. Flexible short pipe with a length of 150-300 mm shall be set at the joint of the ventilation duct and fan, fan case, air handling machine, etc., or according to the design requirements.
The flexible short pipe should not be used as reducing connecting pipe for alignment and leveling. The length of the flexible short pipe located in the structural deformation joint should be more than 100 mm larger than the width of the deformation joint. The installation slope of the air duct conveying condensate or moisture vapor shall meet the design requirements. It is not suitable to set longitudinal joint at the bottom of air duct, and the joint of air duct should be sealed.
- Присоединение фланца вентиляционного канала
Прокладочный материал следует использовать вместо плотной бумаги, картона, асбестовой веревки, свинцово-масляного конопляного волокна и бумаги для линолеума. Стык прокладочного материала должен быть максимально уменьшен. Стык прокладочного материала должен иметь форму трапеции или шипа и прочно приклеиваться. Ширина прокладочного материала после равномерного сжатия фланца должна быть на уровне внутренней стенки воздуховода. Стык между воздуховодом и конструкцией ограждения, такой как потолок и перегородка чистого помещения, должен быть плотным.
- Система вентиляционных каналов должна иметь надежное заземление.
При прохождении вспомогательного производственного помещения он должен быть герметичным, стыковка не должна устанавливаться. Когда температура транспортируемого воздуха выше 80 ℃, необходимо принять меры защиты для воздуховода в соответствии с проектными нормативами. Отверстие для измерения воздуховода должно быть установлено в месте, удобном для измерения и наблюдения; Для измерительного отверстия в воздуховоде в потолке подвижная потолочная пластина или смотровая дверца должны быть зарезервированы в соответствующем месте. При использовании металлического фланца и металлической арматуры для изоляции воздуховода необходимо принять меры для предотвращения конденсации мостика холода на его открытых частях.
- Систему вентиляционных каналов следует проверить на предмет утечки воздуха.
Это последнее звено установки кондиционирования воздуха, но это самое важное звено, поэтому владелец не должен игнорировать это звено при принятии кондиционирования воздуха и должен тщательно проверять, чтобы предотвратить утечку воздуха после установки воздуховода. .

- Здравый смысл в обслуживании воздуховодов
После установки воздуховода, открытые части, такие как горловина воздуховода и горловина фильтра, которые пока не устанавливаются, должны быть своевременно надлежащим образом обернуты пластиковой тканью, чтобы предотвратить попадание пыли в очищенный воздуховод. таким образом вызывая вторичное загрязнение воздуховода.
Я член группы инженеров по установке воздуховодов. Я заранее рад видеть такую статью. Это великолепно