{"id":11622,"date":"2021-07-13T06:17:50","date_gmt":"2021-07-13T06:17:50","guid":{"rendered":"https:\/\/duct.harsle.com\/?p=11622"},"modified":"2024-03-04T08:55:38","modified_gmt":"2024-03-04T08:55:38","slug":"how-to-install-ventilation-duct","status":"publish","type":"post","link":"https:\/\/duct.harsle.com\/pt\/how-to-install-ventilation-duct\/","title":{"rendered":"Como instalar o duto de ventila\u00e7\u00e3o"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Install Ventilation Duct<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Install Ventilation Duct Ventilation duct mainly refers to the ventilation duct of central air conditioning system, which we often ignore it, but it is an important part of air conditioning system. It is a kind of metal or composite pipe for ventilation and air conditioning engineering of industrial and civil buildings. It is a municipal infrastructure to make the air circulate and reduce the concentration of harmful gases.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-classification-of-usage\"><strong>Classification&nbsp;of Usage<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Divided into: supply and return air pipe of the purification system, ventilation pipe of central air conditioning, industrial supply, and exhaust air pipe, suction and exhaust air pipe of the environmental protection system, mine gas drainage pipe, mine rubber-coated cloth air duct, etc. Install Ventilation Duct<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-classification-of-shape\"><strong>Classification&nbsp;of Shape<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Dividido em: duto redondo, retangular, <a href=\"https:\/\/duct.harsle.com\/pt\/how-to-make-the-spiral-duct\/\">duto espiral<\/a>. Install Ventilation Duct<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-classification-of-processing-technology\"><strong>Classifica\u00e7\u00e3o da Tecnologia de Processamento<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Divided into: angle iron flange duct, TDF\u00a0flange duct. Install Ventilation Duct<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized is-style-default\"><img decoding=\"async\" width=\"482\" height=\"379\" src=\"https:\/\/duct.harsle.com\/wp-content\/themes\/woodmart\/images\/lazy.svg\" data-src=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/spiral-duct.jpg\" alt=\"duto espiral\" class=\"wd-lazy-fade wp-image-11614\" style=\"width:595px;height:468px\" title=\"\" srcset=\"\" data-srcset=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/spiral-duct.jpg 482w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/spiral-duct-300x236.jpg 300w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/spiral-duct-15x12.jpg 15w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/spiral-duct-150x118.jpg 150w\" sizes=\"(max-width: 482px) 100vw, 482px\" \/><figcaption><\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-application\"><strong>Aplicativo<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">The\u00a0air duct is mainly used in industrial and construction engineering, and its application fields mainly involve: purification system of the dust-free workshop in electronic industry, purification system of the aseptic workshop for medicine and food, central air conditioning system of hotels, shopping malls, hospitals, factories and office buildings, exhaust duct for dust removal, smoke extraction and oil absorption in industrial pollution control, supply duct for the industrial environment or post comfort, air duct for air-conditioning, air-conditioning system for air-conditioning and air-conditioning Gas drainage system for coal mine gas drainage, air supply and return system for coal mine environment control, etc. Install Ventilation Duct<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-air-duct-construction\"><strong>Constru\u00e7\u00e3o de duto de ar<\/strong><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>For more complex civil buildings, in the design stage, each type of work (HVAC, water supply and drainage, power supply and lighting, and Architecture) should first negotiate the space separation, and determine the elevation range of each kind of pipe. In general, they should not go beyond the limits set for themselves. In case of the crossing of individual pipe sections, it is necessary to negotiate with other projects. Install Ventilation Duct<\/li>\n\n\n\n<li> The principle to solve the collision and coordination of various ventilation pipes is generally: &#8220;small pipes give way to large pipes, and pressure gives way to no pressure&#8221;. For example, if the water pipe collides with the air pipe, the water pipe should be turned. If the cold and hot water pipes collide with the downpipe, the cold and hot water pipes should be changed. Install Ventilation Duct<\/li>\n\n\n\n<li>Before construction, the Engineer in charge of the main equipment shall draw the pipelines and single lines of each type of work on a plan. One-color pen for each type of pipe. Integrate the elevation of each intersection to see if there is any contradiction, find it in time, and solve the problem before installation. Install Ventilation Duct<\/li>\n\n\n\n<li> In order to reduce investment, save space and reduce floor height, some pipes without slope requirements can be laid through beams (such as water pipes, fire spray pipes, etc.). Install Ventilation Duct<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" width=\"640\" height=\"480\" src=\"https:\/\/duct.harsle.com\/wp-content\/themes\/woodmart\/images\/lazy.svg\" data-src=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/duct-installing.jpg\" alt=\"duct installing\" class=\"wd-lazy-fade wp-image-11617\" style=\"width:590px;height:442px\" title=\"\" srcset=\"\" data-srcset=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/duct-installing.jpg 640w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/duct-installing-300x225.jpg 300w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/duct-installing-16x12.jpg 16w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/duct-installing-150x113.jpg 150w\" sizes=\"(max-width: 640px) 100vw, 640px\" \/><figcaption><\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-common-problems-of-air-duct-installation\"><strong>Problemas comuns de instala\u00e7\u00e3o de dutos de ar<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>O material n\u00e3o atende aos requisitos de qualidade<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">This kind of problem is a headache. If the material does not meet the requirements, the air duct will leak when the system is running, which will cause the loss of air conditioning load and affect the service life of the air duct. Install Ventilation Duct<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" width=\"600\" height=\"450\" src=\"https:\/\/duct.harsle.com\/wp-content\/themes\/woodmart\/images\/lazy.svg\" data-src=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/rectangular-duct.jpg\" alt=\"duto retangular\" class=\"wd-lazy-fade wp-image-11613\" style=\"width:599px;height:449px\" title=\"\" srcset=\"\" data-srcset=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/rectangular-duct.jpg 600w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/rectangular-duct-300x225.jpg 300w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/rectangular-duct-150x113.jpg 150w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><figcaption><\/figcaption><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Ru\u00eddo no duto<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Este fen\u00f4meno pode ser causado pela superf\u00edcie irregular, espessura irregular, indenta\u00e7\u00e3o \u00f3bvia, rachadura, buraco de areia, cicatriz e corros\u00e3o da placa, ou afundamento plano do duto de ventila\u00e7\u00e3o, lateral projetando-se para fora e deforma\u00e7\u00e3o \u00f3bvia.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The warping angle, twist and elbow angle of ventilation duct are not accurate Install Ventilation Duct<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">This is due to the inaccurate setting out of plate cutting; The length and width of the sheet metal on the opposite side are not equal; The width of the undercut at the four corners of the ventilation duct is not equal; The setting position of bite seam is wrong, and the force of manual bite seam is different; Taking no corresponding reinforcement measures. In this case, the relative plane of the rectangular duct is not parallel, and the two ends are not parallel; The angle is not straight; The diagonals are not equal;  Install Ventilation Duct<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The bite is not tight. The final direct result is that the air duct connection is uneven, the installed air duct is not straight, the flange gasket is not tight, the system air leakage, resulting in air conditioning load loss, and shortens the service life. Install Ventilation Duct<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-precautions-for-air-duct-installation\"><strong>Precau\u00e7\u00f5es para instala\u00e7\u00e3o de dutos de ar<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large\"><img decoding=\"async\" width=\"600\" height=\"481\" src=\"https:\/\/duct.harsle.com\/wp-content\/themes\/woodmart\/images\/lazy.svg\" data-src=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/rectangular-air-duct.jpg\" alt=\"rectangular air duct\" class=\"wd-lazy-fade wp-image-11612\" title=\"\" srcset=\"\" data-srcset=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/rectangular-air-duct.jpg 600w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/rectangular-air-duct-300x241.jpg 300w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/rectangular-air-duct-15x12.jpg 15w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/rectangular-air-duct-150x120.jpg 150w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><figcaption><\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">1. Verifique a qualidade dos materiais antes da instala\u00e7\u00e3o<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Carefully measure the thickness of the steel plate. Before the installation of the air duct, the factory certificate and material quality certificate of the material must be checked first, and then the appearance of the material must be checked; Then measure the thickness of the steel plate. Prevent rework due to non-conforming materials. Install Ventilation Duct<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. A seguran\u00e7a de i\u00e7amento deve ser garantida<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The hoisting of the clean air duct is the same as that of the ordinary ventilation duct, and the suspender, cross arm, expansion bolt, and lower skid of the insulation air duct are required to meet the relevant specifications and quality acceptance standards. Install Ventilation Duct<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"690\" src=\"https:\/\/duct.harsle.com\/wp-content\/themes\/woodmart\/images\/lazy.svg\" data-src=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Install-duct-1024x690.jpg\" alt=\"Install duct\" class=\"wd-lazy-fade wp-image-11620\" style=\"width:604px;height:408px\" title=\"\" srcset=\"\" data-srcset=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Install-duct-1024x690.jpg 1024w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Install-duct-300x202.jpg 300w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Install-duct-768x518.jpg 768w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Install-duct-1200x809.jpg 1200w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Install-duct-150x101.jpg 150w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Install-duct.jpg 1279w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption><\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">3. Preste aten\u00e7\u00e3o ao desdobrar as etapas de apagamento<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The construction personnel should strictly check the sheet metal, and control the length, width, and diagonal of each sheet metal within the allowable range; After blanking, the two sheets on the opposite side of the air duct should overlap to check the accuracy of the size; The reserved size of sheet bite must be correct to ensure the same width of bite; The biting seam sets at the four corners. When the biting seam is closed by hand, the center of both ends of the biting seam shall be tightened with a wooden hammer, and then the biting seam shall be uniformly compacted along the whole length. Install Ventilation Duct<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4. Fa\u00e7a um bom trabalho de inspe\u00e7\u00e3o de vazamento leve<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">After the ventilation duct assembles on the ground, the light leakage inspection should carry out before the heat preservation. According to the site conditions, the light leakage inspection can be carried out according to the internal or external light leakage, and the sealant shall be added at the light leakage, and the heat preservation can be carried out only when there is no light leakage. Install Ventilation Duct<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" width=\"1024\" height=\"768\" src=\"https:\/\/duct.harsle.com\/wp-content\/themes\/woodmart\/images\/lazy.svg\" data-src=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Air-duct-install.jpg\" alt=\"Air duct install\" class=\"wd-lazy-fade wp-image-11616\" style=\"width:604px;height:453px\" title=\"\" srcset=\"\" data-srcset=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Air-duct-install.jpg 1024w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Air-duct-install-300x225.jpg 300w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Air-duct-install-768x576.jpg 768w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Air-duct-install-16x12.jpg 16w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Air-duct-install-150x113.jpg 150w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><figcaption><\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">5. Teste de vazamento de ar<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For the supply and return air main pipe and branch pipe of purification system with higher grade, besides light leakage inspection, air leakage test shall be conducted after ground assembly. For the smaller system, it can be tested after the installation of the air duct, and for the larger system, it can be carried out after the segmented assembly on the ground as far as possible, so as to find problems and deal with them in time. Install Ventilation Duct<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">6. O material da almofada deve ser bem selecionado<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The gasket at the flange connection of the ventilation duct shall be made of airtight, dust-free, elastic, and non-aging materials, such as closed cell sponge rubber plate, soft rubber plate, etc. the thickness of the gasket shall be 5-8mm. The joint shall be processed into ladder shape, and direct butt joint is strictly prohibited. Install Ventilation Duct<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pode ser resumido em uma frase, como instalar corretamente o duto de ar \u00e9 extremamente importante, a seguir descreve algumas das instala\u00e7\u00f5es de dutos de ar em etapas detalhadas mais abrangentes, reduzir a perda causada por problemas de instala\u00e7\u00e3o.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Certifique-se de que as obras de funda\u00e7\u00e3o sejam conclu\u00eddas antes da instala\u00e7\u00e3o<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The installation of the ventilation duct must be carried out after the completion of these foundation works; Before installation, the appearance quality shall be inspected, and the dust on the inner and outer surface and the debris in the pipe shall be removed. Install Ventilation Duct<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" width=\"750\" height=\"480\" src=\"https:\/\/duct.harsle.com\/wp-content\/themes\/woodmart\/images\/lazy.svg\" data-src=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Air-duct-.jpg\" alt=\"Air duct\" class=\"wd-lazy-fade wp-image-11615\" style=\"width:607px;height:388px\" title=\"\" srcset=\"\" data-srcset=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Air-duct-.jpg 750w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Air-duct--300x192.jpg 300w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Air-duct--18x12.jpg 18w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Air-duct--150x96.jpg 150w\" sizes=\"(max-width: 750px) 100vw, 750px\" \/><figcaption><\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u25cf Duto de ventila\u00e7\u00e3o pr\u00e9-fabricado<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Se n\u00e3o for instalado temporariamente, n\u00e3o deve ser colocado \u00e0 vontade. Todos os orif\u00edcios dos tubos devem ser envolvidos com um pano de pl\u00e1stico e empilhados internamente de acordo com o n\u00famero do sistema, tanto quanto poss\u00edvel. Se as condi\u00e7\u00f5es n\u00e3o permitirem, deve ser empilhado ao ar livre e preste aten\u00e7\u00e3o para colocar a almofada de madeira sob o duto de ar, e deve haver prote\u00e7\u00e3o confi\u00e1vel \u00e0 prova de chuva, areia \u00e0 prova de vento e prote\u00e7\u00e3o solar acima.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u25cf Limpe o duto de ventila\u00e7\u00e3o<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">O duto de ar deve ser limpo com detergente neutro que n\u00e3o cause corros\u00e3o na superf\u00edcie da placa, n\u00e3o produz poeira ap\u00f3s a secagem e n\u00e3o prejudique o corpo humano. Primeiro, limpe com uma solu\u00e7\u00e3o de limpeza, depois limpe com \u00e1gua limpa e, por fim, limpe a marca d&#039;\u00e1gua com um pano branco e limpo. Se n\u00e3o estiver instalado, por enquanto, tamb\u00e9m pode ser secado naturalmente, mas ap\u00f3s a secagem, a sa\u00edda de ar deve ser vedada.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u25cf Mantenha o duto de ventila\u00e7\u00e3o limpo e arrumado<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">O pessoal de instala\u00e7\u00e3o deve usar roupas, luvas e sapatos de trabalho limpos. O duto de ar e seus componentes que foram limpos e selados n\u00e3o devem ser desmontados antes da instala\u00e7\u00e3o. Ao instalar, remova a pel\u00edcula de veda\u00e7\u00e3o da extremidade e, a seguir, conecte o conector; Se houver uma pausa no meio da instala\u00e7\u00e3o, a porta deve ser selada novamente, de forma a garantir a purifica\u00e7\u00e3o do sistema de ar condicionado.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u25cf Nenhuma outra tubula\u00e7\u00e3o deve ser colocada no duto de ventila\u00e7\u00e3o<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">A linha de for\u00e7a do <a href=\"https:\/\/www.sodeca.com\/en\/productos\/in-line-duct-fans-c6\" target=\"_blank\" rel=\"noopener\">ventilador de fluxo axial<\/a>, electric heater, and other equipment installed in the ventilation duct system shall be protected and insulated. The fixed cable of the outdoor riser is strictly prohibited to be pulled on the lightning rod or lightning protection network. When the air duct passes through the wall or floor, it shall not be installed in the wall or floor. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The distance between the air duct and the wall should not be less than 200 mm, and the distance between the air duct and the floor should not be less than 150 mm. When the air duct passes through the fireproof and explosion-proof floor or wall that needs to be closed, the embedded pipe or protective sleeve with the wall thickness of not less than 1.6 mm shall be set, and the flexible material that is non-combustible and harmless to the human body shall be used between the air duct and the protective sleeve.<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" width=\"600\" height=\"450\" src=\"https:\/\/duct.harsle.com\/wp-content\/themes\/woodmart\/images\/lazy.svg\" data-src=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Install-Ventilation-Duct.jpg\" alt=\"Install Ventilation Duct\" class=\"wd-lazy-fade wp-image-11611\" style=\"width:604px;height:453px\" title=\"\" srcset=\"\" data-srcset=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Install-Ventilation-Duct.jpg 600w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Install-Ventilation-Duct-300x225.jpg 300w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/Install-Ventilation-Duct-150x113.jpg 150w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><figcaption><\/figcaption><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>A instala\u00e7\u00e3o do duto de ventila\u00e7\u00e3o deve atender aos requisitos de projeto<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The location of the reserved holes in the building structure should be correct, and the holes should be more than 100 mm larger than the outside size of the air duct. The connection interface between the air duct and the air duct of the building structure should be inserted along the airflow direction, and sealing measures should be taken. Flexible short pipe with a length of 150-300 mm shall be set at the joint of the ventilation duct and fan, fan case, air handling machine, etc., or according to the design requirements. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The flexible short pipe should not be used as reducing connecting pipe for alignment and leveling. The length of the flexible short pipe located in the structural deformation joint should be more than 100 mm larger than the width of the deformation joint. The installation slope of the air duct conveying condensate or moisture vapor shall meet the design requirements. It is not suitable to set longitudinal joint at the bottom of air duct, and the joint of air duct should be sealed.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Conex\u00e3o do flange do duto de ventila\u00e7\u00e3o<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">O material da junta deve ser usado em vez de papel grosso, papel\u00e3o, cordas de amianto, fibra de c\u00e2nhamo de \u00f3leo de chumbo e papel de lin\u00f3leo. A junta do material da gaxeta deve ser reduzida tanto quanto poss\u00edvel. A junta do material da gaxeta deve ser conectada em forma de trap\u00e9zio ou espiga e colada firmemente. A largura do material da gaxeta ap\u00f3s o flange ser comprimido uniformemente deve estar nivelada com a parede interna do duto de ar. A junta entre o duto de ar e a estrutura do inv\u00f3lucro, como o teto e a parede divis\u00f3ria da sala limpa, deve ser estanque.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>O sistema de dutos de ventila\u00e7\u00e3o deve ter boas medidas de aterramento<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ao passar pela sala de produ\u00e7\u00e3o auxiliar, ela deve ser estanque e nenhuma interface deve ser configurada. Quando a temperatura do ar de transporte for superior a 80 \u2103, medidas de prote\u00e7\u00e3o devem ser tomadas para o duto de ar de acordo com os regulamentos de projeto. O orif\u00edcio de medi\u00e7\u00e3o do duto de ar deve ser colocado na posi\u00e7\u00e3o conveniente para medi\u00e7\u00e3o e observa\u00e7\u00e3o; Para o furo de medi\u00e7\u00e3o no duto de ar no teto, a placa de teto m\u00f3vel ou porta de inspe\u00e7\u00e3o deve ser reservada na posi\u00e7\u00e3o correspondente. Quando flange de metal e refor\u00e7o de metal s\u00e3o usados para duto de ar de isolamento, medidas devem ser tomadas para evitar condensa\u00e7\u00e3o da ponte fria em suas partes expostas.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>O sistema de dutos de ventila\u00e7\u00e3o deve ser verificado quanto a vazamento de ar<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Este \u00e9 o \u00faltimo elo da instala\u00e7\u00e3o do ar condicionado, mas \u00e9 o elo mais importante, por isso o propriet\u00e1rio n\u00e3o deve ignorar este link na aceita\u00e7\u00e3o do ar condicionado, devendo verificar cuidadosamente para evitar fugas de ar ap\u00f3s a instala\u00e7\u00e3o da conduta de ar .<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img decoding=\"async\" width=\"700\" height=\"525\" src=\"https:\/\/duct.harsle.com\/wp-content\/themes\/woodmart\/images\/lazy.svg\" data-src=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/HVAC.jpg\" alt=\"HVAC syetem\" class=\"wd-lazy-fade wp-image-11619\" style=\"width:608px;height:456px\" title=\"\" srcset=\"\" data-srcset=\"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/HVAC.jpg 700w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/HVAC-300x225.jpg 300w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/HVAC-16x12.jpg 16w, https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/HVAC-150x113.jpg 150w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/><figcaption><\/figcaption><\/figure>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Bom senso de manuten\u00e7\u00e3o de dutos de ar<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Ap\u00f3s a instala\u00e7\u00e3o do duto de ventila\u00e7\u00e3o de ar, as partes abertas, como a boca do duto de ar e a boca do filtro que n\u00e3o est\u00e3o instaladas no momento, devem ser devidamente embrulhadas com um pano pl\u00e1stico a tempo de evitar que a poeira entre no duto de ar limpo, causando polui\u00e7\u00e3o secund\u00e1ria no duto.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>Install Ventilation Duct Install Ventilation Duct Ventilation duct mainly refers to the ventilation duct of central air conditioning system, which<\/p>","protected":false},"author":1,"featured_media":11618,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[200],"tags":[210,215,214,182],"class_list":["post-11622","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ventilation-duct","tag-air-duct","tag-air-duct-fabrication","tag-air-duct-installation","tag-hvac-air-duct"],"jetpack_featured_media_url":"https:\/\/duct.harsle.com\/wp-content\/uploads\/2021\/07\/How-to-Install-Ventilation-Duct.jpg","jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/duct.harsle.com\/pt\/wp-json\/wp\/v2\/posts\/11622","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/duct.harsle.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/duct.harsle.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/duct.harsle.com\/pt\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/duct.harsle.com\/pt\/wp-json\/wp\/v2\/comments?post=11622"}],"version-history":[{"count":0,"href":"https:\/\/duct.harsle.com\/pt\/wp-json\/wp\/v2\/posts\/11622\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/duct.harsle.com\/pt\/wp-json\/wp\/v2\/media\/11618"}],"wp:attachment":[{"href":"https:\/\/duct.harsle.com\/pt\/wp-json\/wp\/v2\/media?parent=11622"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/duct.harsle.com\/pt\/wp-json\/wp\/v2\/categories?post=11622"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/duct.harsle.com\/pt\/wp-json\/wp\/v2\/tags?post=11622"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}